Sanyo VCC-MCH5600 Digital Camera User Manual


 
9
Control/Address Settings
When you connect the camera to a controller, it is necessary to configure the interface board control
switch and address switch.
Control switch
This is used to configure transmission rate and protocol, etc.
Switches 4 and 5 are not used.
Settings in bold typeface in the table below show the factory default
configurations.
Baud Rate
Configure the transmission rate of connected devices to the transmission
rate of the camera.
Transmission Rate Switch 1 Switch 2
2400 OFF OFF
4800 ON OFF
9600 OFF ON
19200 ON ON
When protocol is set to “PELCO”, set to 2400.
Protocol
Select the protocol for controlling the camera.
Protocol Switch 3 Corresponding Protocol
SSP (SANYO) OFF Automatic switching between Sanyo SSP and high speed SSP
PELCO ON Automatic switching between PELCO-D and PELCO-P
Terminator
When you connect multiple cameras, set the terminator setting (Switch 6) of the final device to “ON”
and all other devices to “OFF”.
Address switch
When you connect multiple cameras, allocate a unique RS485 protocol address (camera number) to
each camera.
ON
12345678
Configure the address by setting the dip switches to “ON” and “OFF”.
For further information, refer to the “Address Settings Table” on
the next page.
ON
123456
ON
123456