Sony XCD-V60CR Digital Camera User Manual


 
Control
24
Actual control can be carried out by setting registers
from F0F00800 onward.
ddd indicates the control value expressed as a 12 bit
hexadecimal number.
xxx indicates that any setting made will be ignored.
Brightness control
AE reference control
Sharpness control
White balance control
Hue (G level) control
Saturation control
Gamma control
Shutter (exposure time) control
Gain control
Trigger control
Trigger Delay control
Address Data
F0F00800 82000ddd Adjusts the black level.
Address Data
F0F00804 82000ddd Sets the AE reference value.
Address Data
F0F00808 82000000 Sets to the soft image quality.
82000007 Sets to the sharp image quality.
Address Data
F0F0080C 82BBBRRR Adjusts the white balance
manually.
83xxxxxx Adjusts the white balance
automatically.
86xxxxxx Perform the one-push auto
white balance function.
Address Data
F0F00810 82000ddd Sets the green video level.
Address Data
F0F00814 82000ddd Adjusts the color intensity.
Address Data
F0F00818 82000000 Sets Gamma to OFF.
82000001 Reverses the black and white.
82000002 Sets the gamma curve
equivalent to 0.7.
82000003 Sets an optional gamma curve
by a user. (See “LUT.”)
Address Data
F0F0081C 82000ddd Controls shutter using the
manually set relative value.
83000xxx Sets the shutter control to
AUTO (relative value).
C2000xxx Controls shutter using the
manually set absolute value.
C3000xxx Sets the shutter control to
AUTO (absolute value).
F0F00978h
(To obtain
this address,
see “The
formula for
absolute
value shutter
control
register
address” on
page 25.)
Determines
the optional
value using
the 32-bit
floating-
point format.
After F0F0081C has been set
to the absolute value control,
set the exposure time using
this register.
Address Data
F0F00820 82000ddd Set Gain manually.
83000xxx Set Gain to AUTO.
Address Data
F0F00830 82000000 Sets to Hardware Trigger
Mode0.
82010000 Sets to Hardware Trigger
Mode1.
820E000d Sets to Hardware Trigger
Mode14.
820F000d Sets to Hardware Trigger
Mode15.
82E00000 Sets to Software Trigger
Mode0.
82E10000 Sets to Software Trigger
Mode1.
82EE000d Sets to Software Trigger
Mode14.
82EF000d Sets to Software Trigger
Mode15.
F0F0062C 80000000 Outputs a software trigger. In
Trigger Mode0, automatically
resets to 0 when exposure
ends.
00000000 In Trigger Mode1, ends
exposure if “0” is set.
Address Data
F0F00834 82000ddd Sets Trigger Delay.