Speco Technologies SIPD3 Security Camera User Manual


 
2-34
1.
3. INDOOR2: Select the indoor white balance profile
2.
4. OUTDOOR1: Select the outdoor white balance
profile 1.
5. OUTDOOR2: Select the outdoor white balance
profile 2
6. HOLD CURRENT: Select this to let the IP
camera automatically obtain a best white balance
setting according to current environment. The IP
camera will use this setting to adjust color.
NOTE: This setting will be lost after you
reboot the camera.
7. MANUAL: Select this to enable manual setting of
the white balance. You will need to enter the R
Gain and B gain setting below.
R Gain
(Manual White balance
mode only)
Add or decrease redness to the video when under Manual
White Balance mode. (This function is only available in
Manual White balance mode.)
B Gain
(Manual White balance
mode only)
Add or decrease blueness to the video when under
Manual White Balance mode. (This function is only
available in Manual White balance mode.)
Exposure mode
Select exposure mode to auto or manual.
- Auto: The IP camera will adjust the exposure
automatically.
- Manual: (In Manual White balance mode only)
Manually select the Exposure Gain and Shutter
Speed below.
Exposure Gain
Select the exposure Gain of the IP camera. The higher the
value = brighter images.
Shutter Speed
Increase or decrease the shutter speed. The closer the
number is to 1, the better nighttime performance is,
although this also causes motion blur to the video.
AGC Gain
(In auto Exposure
mode only)
When exposure mode is auto, IP camera will adjust its
shutter speed according to AGC gain and the Maximum
auto shutter speed. Higher AGC gain = brighter images.
Maximum Auto
Shutter Speed
(In auto Exposure
mode only)
When exposure mode is auto, IP camera will adjust its
shutter speed according to AGC gain and the Maximum
auto shutter speed. This setting is to set the maximum
shutter speed range of this camera.
Flickless Mode
Change settings between 60Hz or 50Hz, depending on
the AC power type of your region.
STEP 2: Click the
[Apply] button of each setting to confirm the
settings or click the [Reset] button to re-enter the parameters.