Speco Technologies SIPSD10X Security Camera User Manual


 
2-71
A. Dome Setup
To enter Dome setup, use the five keys right to move when cursor on
dome setup.
A-1. DOME SET - CAMERA ID
To set camera ID, select up to 16 characters using five keys to the left or
right.
Press ZOOM TELE button to move to the next character from left to right
direction and
ZOOM WIDE button to move to the next character from right to left
direction (Space displays when appears)
A-2. DOME SET - RECOVER
This feature allows the dome to work from the last setting before you use
the dome manually
(Auto scan, group tour, preset, pattern or sectors) , after the set time,
even power shut down and it turns on again. Recover time can be
programmed from 15 second to 99 seconds. The default setting is OFF.
A-3. DOME SET - MANUAL SPEED
Manual Speed of Pan/Tilt is selectable from 100°/sec up to 150°/sec.
The default setting is 100°/sec
A-4. DOME SET - AUTO FLIP
Auto Flip is available and the default setting is OFF. Move five keys
DEFAULT SETTING
DOME SET
CAMERA ID :
CAM1□□□□□□□□□□□□
RECOVER : OFF
MANUAL SPEED : 100°/S
AUTO FLIP : OFF
ZOOM SPEED : FAST
ALARM : DISABLE
LANGUAGE : ENGLISH
[NEXT PAGE]
SAVE AND EXIT
EXIT