Speco Technologies SIPSD10X Security Camera User Manual


 
2-81
E. TOUR SET
8 Programmable tours can be set and each tour is available to set up to 64
preset steps.
E-1. TOUR SET – TOUR NO.
Max. 8 group tour no. set by the five keys are available.
E-2. TOUR SET – TOUR TITLE
To set tour title, select up to 16 characters using Five keys to left or
right.
Press ZOOM TELE button to move the next character from the left to the
right direction and ZOOM WIDE button to move the next character from
the right to left direction (Space displays when appears) Tour title is
not displayed on the monitor, but only for the reference of user.
E-3. TOUR SET – TOUR STEP
Each tour group consists of up to 60 preset steps with different dwell
time and speed. It is possible to match any preset # for each tour step.
E-4. TOUR SET – PRESET NO.
The decided tour step #1 ~64, it is possible to select any preset no. up to
64. The default setting is BLK
E-5. TOUR SET – DWELL TIME
Dwell time provides up to 99 seconds from 01 second. The default
TOUR SET
TOUR NO : 01
TOUR TITLE :
TOUR01□□□□□□□□□□
TOUR STEP : 01
PRESET NO. : 01
DWELL TIME : 03
SPEED : 200°/S
SAVE
EXIT
DEFAULT SETTING