4
Changing HD/VD input/output
(1) Put off 6 screws both on flank/top of camera chassis.
(2) Change internal switch SJ01(HD/VD).
SJ01
HD/VD OUTPUT
HD/VD INPUT high-impedance
HD/VD INPUT 75 (factory setting)
The shutter speed can be set by the horizontal scanning period (1H) or by the frame. Also, CCD integration
mode can be set.
1
Setting by 1H
260/525H to 1/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (63.56ms).
2
Setting by the frame
1FRM to 255FRM (at field storage) and 2FRM to 256FRM (at frame storage) stand for the setting (long
period exposure) by the frame.
(a) Field storage period
The video signal stored during the frame period set is output as 1 field video image at a frame interval
specified.

ư

ư
Index output
2FRM setting
Video output
VD output
(INDEX)
(b) Frame storage period
The video signal stored during the frame period set is output as 1 frame video image in a frame interval.

ư

ư

ư

ư
Index output
2FRM setting
Video output
VD output
+0&':
7'
''