24
7. 3 Synchro. Scan Operation
The shutter speed can be set by the horizontal scanning period (1H) or by the frame.
( 1 ) Setting by 1H
1H/525H ~ 524H/525H stands for the setting by the 1H and the shutter speed can be set by the 1H (31.8 µs).
When operating Partial Scannig, the number’s listed below can be used for setting.
Partial scanning OFF 1H/525H ~ 524H/525H
90fps, E90fps 1H/348H ~ 347H/348H
115fps, E115fps 1H/272H ~ 271H/272H
120fps, E120fps 1H/262H ~ 261H/262H
160fps, E160fps 1H/197H ~ 196H/197H
180fps, E180fps 1H/175H ~ 174H/175H
240fps, E240fps 1H/131H ~ 130H/131H
( 2 ) Setting by the frame
2FRM to 512FRM stand for the setting (long period exposure) by the frame.
The video signal stored during the frame period set is output as 1 frame video image at a frame interval
specified.
(4FRM setting)
n n+1
RGB data
(video interval image)
(Internal VD)
FVAL
LVAL,
DAVL
( 7 ) Returning to factory settings
All the settings can be returned to the factory default status (preset status).
(1) If characters are displayed on the screen, press the [DISP] button to disable the character display.
(2) Push [MENU DOWN] and [DATA DOWN] buttons simultaneously for approx. 1 second.
(3) The preset operation starts. When the preset operation finishes, the character PRESET OK is displayed
for approx. 1 second.