cyclesize 16~ 6/6 The maximum size for cycle recording in Kbytes
when choosing to limit recording size.
reserveamount 0~15000000 6/6 The reserved amount in Mbytes when choosing cyclic
recording mechanism.
dest cf,
0, 1, 2, 3, 4
6/6 The destination to store the recorded data.
“cf” means local storage (CF or SD card).
“0” means the index of the network storage.
cffolder string[128] 6/6 Folder name.
trigger schedule,
networkfail
6/6 The event trigger type
schedule: The event is triggered by schedule
networkfail: The event is triggered by the failure of
network connection.
adaptive_enable 0,1 6/6 Indicate whether the adaptive recording is enabled
adaptive_preevent 0~9 6/6 Indicate when is the adaptive recording started before
the event trigger point (seconds)
adaptive_postevent 0~10 6/6 Indicate when is the adaptive recording stopped after
the event trigger point (seconds)
5.28. HTTPS
Group: https (capability.protocol.https > 0)
NAME VALUE SECURITY
(get/set)
DESCRIPTION
enable <boolean> 6/6 To enable or disable secure HTTP.
policy <Boolean> 6/6 If the value is 1, it will force HTTP connection
redirect to HTTPS connection
method auto,
manual,
install
6/6 auto => Create self-signed certificate automatically.
manual => Create self-signed certificate manually.
install => Create certificate request and install.
status -3 ~ 1 6/7 Specify the https status.
-3 = Certificate not installed
-2 = Invalid public key
-1 = Waiting for certificate
0 = Not installed
1 = Active
countryname string[2] 6/6 Country name in the certificate information.
stateorprovincename string[128] 6/6 State or province name in the certificate information.
localityname string[128] 6/6 The locality name in the certificate information.
organizationname string[64] 6/6 Organization name in the certificate information.