Vivotek FD8365EHV Security Camera User Manual


 
VIVOTEK
180 - User's Manual
exttriggerstatus1 trigger,
normal~trigger
,
trigger~norma
l
<blank> 6/6 The status for event audio detection
profile trigger
di <integer> 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin <integer> 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 <integer> 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
vi <integer> 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
One bit represents one digital input.
The LSB indicates VI 0.
valevel 0,1 0 6/6 Select audio detection event.
0: not select
1: select
Valevel0 0,1 0 6/6 Select audio detection profile event.
0: not select
1: select
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger