Vivotek IP2122 Security Camera User Manual


 
49
Appendix
A. Troubleshooting
Status LED
After the power has been turned on, Network Camera will perform a self-diagnostic to
detect any hardware defects. The following table lists the LED patterns in general
conditions. In case of any fatal error, the LED will blink in another pattern.
Condition LED color
During self-diagnostic after power on Blink in interchanged green and red
Ethernet signal is lost Steady red till Ethernet is detected
Before network is setup No LED of sign till IP address is set
After network is setup Blink green once per second
Any hardware failure Other patterns
Reset and restore
Sometimes resetting the system can make the system
back to normal state. If the system still has problems after
reset, restore the factory settings and install again.
RESET: Poke the wrench to click on the button.
RESTORE:
1. Poke the wrench to press on the button continuously.
2. Wait for self-diagnostic to run twice.
3. Withdraw the wrench as soon as the second
self-diagnostic starts.
Restore the factory defaults will lose any previous settings. Reset or restore the
system after power on.