edge switch 2/16 service manual 2–11
Diagnostics
↓
Go to step 14.
11
Click the icon representing the switch reporting the problem. The Hardware View
displays. At the Hardware View:
• Observe whether the edge switch 2/16 Status table is yellow and switch status is
NOT OPERATIONAL.
• Inspect FRUs for a blinking red and yellow diamond (failed FRU indicator) that
overlays a FRU graphic.
Does a blinking red and yellow diamond overlay a Fibre Channel port graphic?
NO YES
↓
A port SFP failure is indicated. Go to step 23 to obtain event codes. If no
event codes are found, go to "
MAP 0600: Port Failure and Link Incident Analysis
"
on page 2-63.
12
Does a blinking red and yellow diamond overlay a fan graphic?
NO YES
↓
A fan failure is indicated. Go to step 23 to obtain event codes. If no event
codes are found, go to "
MAP 0500: Fan and CTP Failure Analysis
" on page 2-58.
13
A blinking red and yellow diamond overlays a power supply graphic.
A power supply failure is indicated. Go to step 23 to obtain event codes. If no event
codes are found, go to "
MAP 0100: Power Distribution Analysis
" on page 2-26.
14
Does a yellow triangle (attention indicator) appear at the alert panel and as the
background to the icon representing the switch reporting the problem?
YES NO
↓
Go to step 18.
15
Click the icon representing the switch reporting the problem. The Hardware View
displays. At the Hardware View: