167
MVP MANUAL
(15) Vertical compression filter conversion rate input [LCV command]
Input : LCVd1d2d3d4
Explanation :• d1d2=00 to 15 (Add 0 before all numbers below 9) Vertical direction rate before conversion
•d
3d4=00 to 15 (Add 0 before all numbers below 9) Vertical direction rate after conversion
Due to the use of a compression filter, the condition is d
1d2
>
d3d4.
Both LCV0000 and LCV0101 are not convertible.
• Directly changes the vertical filter conversion rate of the data table of the model using the VS
board currently.
• When the conversion rate is changed for DSY, the image compressed by the new conversion rate
will be output.
(Example)
: LCV0605 Set 6–>5 conversion
(16) Program ROM version display [VER command]
Input : VER
Explanation :• Indicates the version of the program ROM mounted in the current VS board.
(Example)
: VER
PROGRAM VERSION=BXY1004-X VX.XX 199X.XX.XX
(17) To indicate the current function setting [STS command]
Input : STS
Explanation :• Displays the model data No., selected state (auto or forced), vertical filter ON, OFF, and freeze
ON, OFF selected by the VS board currently.
(Example)
: STS
STATUS=DSY, FZN
MODEL NO.=09 AUTO
: STS
STATUS=DSY, FZN
MODEL NO.=03 FIXED
=
Autolocks to PC9801 with the left display, indicates vertical
filter ON, freeze OFF.
Forcible locks the Macintosh with the left display, indicates
vertical filter ON, freeze OFF.