172
MVP MANUAL
(23) Vertical frequency input [VFQ command]
Input : VFQd1d2d3.d4d5d6
Explanation :• Directly changes the horizontal frequency of the model data table used for the VS board cur-
rently.
• Input the frequency using 6-digit decimal numbers. When data input is omitted, the vertical fre-
quency on the current model data table is displayed.
Although numbers outside the vertical specification range (55.0 kHz to 72.0 kHz) range of this
board can be input, they cannot be used as preset data.
• Refer to “Using Methods of HFQ, VFQ, VLN” described later on the using methods.
(Example)
VFQ060.123 Input 60.123 kHz
(Take note to input 0 at first.)
(24) Vertical full-line input [VLN command]
Input : VLNd1d2d3
Explanation :• 3-digit decimal numbers between 000 to 999 can be input for ddd.
• Directly changes the vertical full line number of the model data table used for the VS board
currently.
• Refer to “Using Methods of HFQ, VFQ, VLN” described later on the using methods.
(25) All reset [ARS command]
Input : ARS
Explanation :• Sets back the adjustment data, etc. memorized by the VS board to the shipment values.
• As all the data registered by the user are set back to the initial values, use this command care-
fully.