Anton/Bauer AJ-HDX400E Camcorder User Manual


 
Chapter 6 Maintenance and inspections
76
6-3-3 Emergency eject
If the cassette cannot be ejected by pressing the EJECT button, use a screwdriver or similar tool to press and turn the
emergency eject screw. This enables the cassette to be removed.
1
Set the power to OFF.
4
Remove the cassette.
5
Return the rubber cap to its original position.
2
Remove the rubber cap where shown in the figure. Insert
a Phillips head screwdriver into the cross-shaped part of
the emergency eject screw (red).
3
While pushing in with the screwdriver, turn the emergency
eject screw counterclockwise until the tape is ejected.
This screw needs to be rotated through about 20 turns
after the first turn until the unloading can be started.
It also needs to be rotated through about 90 turns after
the first turn until the tape is ejected.
2, 5
3
Cassette holder
Emergency
eject screw
Push in and turn at
the same time.
<Notes>
Do not turn the emergency eject screw except in an
emergency.
Do not turn the screw clockwise. Stop turning the
screw as soon as the tape is ejected. Otherwise, the
mechanism may be damaged.
After the tape is ejected, the cassette holder will not lock
into place even when an attempt is made to close it. Be
sure to turn the power off and turn it back on to reset the
mechanism’s operation, and then close the cassette holder.
A clicking sound will be heard when the emergency eject
screw is turned: this sound is made by the reel drive
operation and is therefore not indicative of a malfunction.
6-3-2 Error codes
One of the following error codes appears in the display
window when an error has occurred in the unit for some
reason.
Code No. Description of error
04 Pinch solenoid problem
08 Cleaning solenoid problem
0B Supply reel problem
0C Take-up reel problem
0D Capstan problem
0E Cylinder problem
0F Loading problem
38 Servo transmission problem
3F Camera transmission problem
6F Reference signal problem
11 Video initialization problem