Chapter 7 Menu description tables
93
7-8 VTR MENU
7-8-1 VTR FUNCTION
ECU REC CHK SW R.REVIEW
RETAKE
For setting the unit’s operation to be
performed using the REC check button on the
ECU.
R.REVIEW: The rec-review operation is
performed.
RETAKE: The retake operation is
performed, after which playback
is initiated automatically.
<Note>
To use rec review, select REC CHECK as the
RET SW item setting on the <7-5-5 SW
MODE> page.
Item/
Data storage
Variable
range
Remarks
HUMID OPE ON
OFF
For selecting whether or not to continue
operation when HUMID alarm state has
occurred.
ON: Operation continues until tape slack is
detected even when the HUMID alarm
state has occurred during operation.
OFF: Operation is stopped as soon as the
HUMID alarm state occurs.
If the HUMID alarm state occurs during
recording, the recording operation will
continue unless tape slack is detected
regardless of whether ON or OFF has been
selected as this item’s setting.
REC START ALL
NORMAL
For selecting how recording start is to be
accepted.
PAUSE TIMER 10min
20min
30min
60min
For selecting the time during which REC/
PAUSE is to continue.
7-7-4 BLACK SHADING
Item/
Data storage
Variable
range
Remarks
CORRECT ON
OFF
For selecting ON or OFF for the digital black
shading compensation.
DETECTION
(DIG)
—
For executing the digital black shading
compensation.
7-7-5 WHITE SHADING
Item/
Data storage
Variable
range
Remarks
CORRECT ON
OFF
For selecting ON or OFF for the white shading
compensation.
DETECTION
(V SAW)
–
For executing the white shading
compensation.
CUFE
CUFE
CUF
CUF
CUF
CUF
The underlining in the variable range column indicates the setting in the preset
mode.
BATTERY SELECT AJ-BP490
AU-BP402
HP-30A
PRO14
TRIM14
HYTRON50
HYTRON100
DIGITAL14
DIGITAL13
DIONIC
BP-H120
NP-L50
NP-L50D
ENDURA50
ENDURA80
ENDURA-D
BP-L60/90
NP-1B
TYPE A
TYPE B
For selecting the type of battery to be used.
The remaining charge is detected in
accordance with the battery which has been
selected.
The variable range is changed by the item
settings selected on the “7-8-3 BATTERY
SETTING1” and “7-8-4 BATTERY
SETTING2” menus.
Note that the initial value for TYPE A
corresponds to the PROFORMER and for
initial value for TYPE B to the HYTRON100,
both of which are manufactured by Anton
Bauer.
BATT NEAR END
ALARM
ON
OFF
For setting whether or not to output the
warning tone when the battery charge is
nearly depleted.
TAPE NEAR END
ALARM
ON
OFF
For setting whether or not to output the warning
tone when the tape is nearly at its end.
TAPE NEAR END
TIME
3min
2min
For setting the remaining tape time at which
to sound the warning that the tape has only
the designated amount of time (2min. or
3min.) remaining.
TAPE END ALARM ON
OFF
For setting whether or not to output the
warning tone when the tape reaches the end.
BATT REMAIN
FULL
100%
70%
For setting when the remaining charge display
bar on the LCD is to be displayed when a
digital battery is used.
70%: A full charge is indicated with a 70% display
100%:A full charge is indicated with a 100% display.
BATT NEAR END
CANCEL
ON
OFF
When this item is set to ON, the warning tone
and the warning display which are being
output can be canceled by pressing the
MODE switch when the battery charge is
nearly depleted.
BATT END ALARM ON
OFF
For setting whether or not to output the warning
tone when the battery charge is depleted.
TAPE REMAIN/∫ 5min/∫
3min/∫
For setting the time of each segment (∫) that
makes up the remaining time display bar on
the LCD.
5min: Each segment denotes a remaining
time of 5 minutes.
3min: Each segment denotes a remaining
time of 3 minutes.
7-8-2 BATTERY/TAPE
Item/
Data storage
Variable
range
Remarks
EXT DC IN
SELECT
AC_ADPT
AJ-BP490
AU-BP402
HP-30A
PRO14
TRIM14
HYTRON50
HYTRON100
BP-H120
NP-L50
ENDURA50
ENDURA80
BP-L60/90
NP-1B
TYPE A
TYPE B
The variable range is changed by the item
settings selected on the “7-8-3 BATTERY
SETTING1” and “7-8-4 BATTERY
SETTING2” menus.
CUF
CUF
CUF
CUF
CUF
CUF
CUF
CUF
CUF
CUF