Axis Communications AXIS 225FD Digital Camera User Manual


 
46
AXIS 225FD - System Options
Resetting to the Factory Default Settings
To reset the camera to the original factory default settings, go to the System Options >
Maintenance web page (as described in Maintenance, on page 44) or use the Con
trol
button (see the illustrati
on on page 6) as described below:
Using the Control Button
To reset the camera to the factory default settings using the Control Button:
1. Disconnect the power adapter, or the network cable if using PoE.
2.
Press and hold the Control button while reconnecting power.
3. Keep the Control button pressed until the Status Indicator color changes to
amber (which may take up to 15 seconds).
4. Release the Control button.
5. When the Status Indicator changes to Green (which may take up to 1 minute), the
process is complete and the camera has been reset. The unit will now have the
default IP address 192.168.0.90