Bosch Appliances LTC 9385 Security Camera User Manual


 
LTC 9385 Series | Instruction Manual | Installation
EN
|
11
Bosch Security Systems | January 26, 2005
Recommended Maximum Cable Lengths
Models Wire Size Distance
mm
2
AWG meters feet
-1 (115 VAC) 1.5 16 1000 3280
2.5 14 1600 5250
4122500 8200
-2 (24 VAC) 0.5 22 10 30
0.5 20 15 50
118 2580
1.5 16 40 120
2.5 14 70 210
-4 (230 VAC) 1.5 16 4000 13000
2.5 14 6400 21000
41210000 32800
1. Use the liquid-tight fitting on the left of the
housing to route the power supply cord into the
housing.
2. Allow enough cord for connection to the
terminal block; approximately, 130mm (5in.).
Strip no less than 6mm (0.24in.) and no more
than 8mm (0.31in.) of insulation away from the
wires making sure not to nick the wires.
3. A screw/terminal lug is provided for securing a
safety ground. To attach the safety grounding
wire of the power cord (green 115volt,
green/yellow 230volt), first unscrew the terminal
lug and strip and crimp the grounding wire into
the lug. Next, reattach the terminal lug to the
rail assembly using the M4 x 10 screw and lock
washer provided. See FIGURE 8.
FIGURE 8 Securing the Ground Wire
4. Connect both the line and neutral wires of the
power cord to the terminal block. Make sure
the line and neutral wires are connected to the
correct positions on the terminal block that are
across from the appropriate colored wire. See
FIGURE 9.
FIGURE 9 Attaching Line and Neutral Wires
5. Pull any excess cord through the liquid-tight
fitting and tighten the flex fitting to 8.5N-m to
9.0N-m (75in. lb to 80in. lb). This torque rating
is approximately 1 to 1 1/2 turns past the point
that the fitting starts to grip the cord. Failure to
do so will result in water damage to all
electronic parts. Use a tie wrap (included) to
provide strain relief on the power cord at the
exit point (inside the unit).
Securely tighten all fittings to ensure a liquid-
tight seal. Not doing so could damage the
camera, the housing, or both.
5.8.2 Camera Power Connections
LTC 9385/60 Housings
These housings are to be connected to 115VAC, and
are designed for use where site power is 115volts. The
LTC 9385/60 housings should only be used with
115volt cameras. The integral heater/defogger
requires 115volts. The housing is shipped with the
heater/defogger connected to the terminal block.
Installing a 115 volt camera into the LTC 9385/60
housing simply requires the camera's line cord to be
plugged into the NEMA 5-15R receptacle provided.
See FIGURE 10.