Bosch Appliances VG4-500I Security Camera User Manual


 
118 en | Troubleshooting Guide VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
No camera control Ensure that the keyboard and monitor are set to the correct (same) camera number.
If O.K., then:
Check that the camera address is properly set. Enter ON-997-ENTER to display the
camera address.
If address is not set or is incorrect, then:
Set the camera address using FastAddress (ON-998-ENTER).
If O.K., then:
Check that the Amber LED on the AutoDome CPU turns on when receiving pan/tilt
commands from the controller keyboard. The Amber LED indicates control is being
received.
Amber LED on AutoDome CPU Module
Flash Sequence
–Off
No incoming communications or no power
Solid for 2 seconds
Receiving good data
Fast blinking
Lost packet(s)
If amber LED does not light when given PTZ commands, then:
Check if other cameras on the system can be controlled. If not, check the controller
and wiring connections.
If O.K., then:
Check that the RS-232/485 selector switch is properly set to the proper protocol.
If O.K., then:
Ensure that all Biphase, Bilinx, or RS-232/485 wires are properly connected. See the
AutoDome Modular Camera System Installation Manual.
If O.K., then:
Check if you can access the AutoDome OSD menus (ON-46-ENTER).
If O.K., then:
Confirm that the AutoDome passes homing (SET-110-ENTER).
If AutoDome fails homing, then:
Contact Bosch Technical Support.
Intermittent camera
control
Check that only the last AutoDome in a daisy chain configuration is terminated with a
110 Ω resistor across the +/- biphase terminals.
If O.K., then:
Check that the maximum wire distance has not been exceeded for the control protocol
(the maximum distance for RS-232 is 50 feet). See the AutoDome Modular Camera
System Installation Manual.
If O.K., then:
Check that all wiring meets Bosch recommended standards and specifications. See the
AutoDome Modular Camera System Installation Manual.
Camera moves when
moving other
cameras
Check that the camera address is properly set (ON-997-ENTER). If the camera address
is not set, the AutoDome responds to control commands to any camera on the system.
If camera address is not set, then:
–Invoke the FastAddress Menu to assign a camera address (ON-998-
ENTER).
Cannot access user
settings
Enter the unlock command OFF-90-ENTER. This command may require a password.
(Commands automatically lock in 30 minutes.)