Bosch Appliances VG4-500I Security Camera User Manual


 
VG4 Modular Camera System Advanced Features | en 49
Bosch Security Systems, Inc. User’s Manual F.01U.133.268 | 6.0 | 2010.03
2. Click the Online Config button and then expand Alarm.
Figure 7.2 Expanded Alarm Group
3. Expand Output Options; then click Output Option 5.
4. Select Tracking from the Type drop-down list.
5. Click Output Option 6.
6. Select Shot from the Type drop-down list.
7. Type the number 1 or use the slide bar to specify shot number 1. (Shot numbers must be
set prior to configuring an alarm rule. See Section 3.2 Setting Preset Shots, page 30, for
instructions).
The AutoDome moves to this preposition when the alarm rule is true.
Figure 7.3 Output Option 6 Configuration
8. Expand Alarm Rule; then click Alarm Rule 1.
9. Click the Yes radio button to enable the rule.
10. Type the number 1 or use the slider bar to select 1 for the Input option.
11. Select Alarm Input 1 from the Input Option drop-down list.
12. Ensure that the Output number is set to 1.