Bosch Appliances VG4-500I Security Camera User Manual


 
20 en | On-Screen Display Menu Navigation VG4 Modular Camera System
F.01U.133.268 | 6.0 | 2010.03 User’s Manual Bosch Security Systems, Inc.
Communication Setup Menu Choices:
2.7 Alarm I/O Setup
The Alarm Setup Menu provides access to the Alarm I/O Setup Menu to establish the alarm
inputs and outputs and to configure alarm rules.
Menu items marked with the ‡ symbol are available only with VG4 Pressure Domes.
Menu Description Sub-menu / Description Default
Setting
Exit Saves and exits the menu.
AutoBaud Turns AutoBaud detection on. Toggles ON or OFF.
ON automatically accepts baud
rates from 2400 to 57600.
(Note: If stepping from 2400 to
57600 baud, you must first set the
controller to 19200 for AutoBaud
to detect the higher baud rate.)
ON
Baud Rate Manually sets the baud rate when
AutoBaud is set to OFF.
Choices are 2400, 4800, 9600,
19200, 38400, and 57600. Then
follow the OSD to confirm the
selection.
9600
Bilinx Turns on Bilinx control
communication.
(Only available when not
connected to a Bilinx data
interface unit.)
Toggles ON or OFF.ON
NOTICE! Bilinx protocol is not available with IP cameras.
Alarm I/O Setup Inputs Setup
Exit... Exit...
Inputs Setup... 1. Alarm Input 1 N.C.S.
Physical
Input 1-7
Outputs Setup... 2. Alarm Input 2 N.O.S.
Rule Setup... 3. Alarm Input 3 N.O.
Restore Defaults... 4. Alarm Input 4 N.C.
5. Alarm Input 5 N.O.
6. Alarm Input 6 N.C.
7. Alarm Input 7 N.O.
8. Low Pressure‡
9. NONE
Physical
Output 9-12
10. NONE
11. NONE
12. NONE
Focus / Iris: Select Type
Focus / Iris: Select Right / Left: Select Mode