4-2 How to Connect the Cables
(1) Prepare the coaxial cable end as shown
(Fig. 15).
(2) Connect the coaxial cable and power cables to
the terminal strip.
Insert the core underneath of the appropriate
locking washer fitting, and fasten the screw.
Secure the shielding wire to the coaxial cable
fixing metal fitting with the screws (Fig. 16).
* If you wish to run the coaxial cable
outside of the wall or ceiling, use
optional metal fittings for wall
(EB-413B).
(3) Connect cables to the monitor TV and power
source.
Unit : mm (inch)
(Fig. 15)
(Fig. 16)
Locking washer
Coaxial cable lock
metal fitting
Core Shielding wire
4-3 Notes in Use
1. Use this unit indoors. Do not mount it outdoors.
2. When the cover needs cleaning, wipe it with a soft cloth.
Do not use alcohol, thinner or the like.
3. If a part of the image is exposed to strong light, such as light bulb, the auto iris may be activated to
darken the screen. In this case, change the direction or adjust the iris with the ALC adjust volume.