JVC 257VP Security Camera User Manual


 
Specify tcpto, IP address, port number, none or object(Number), and the character string to be sent when sending
via TCP. Segments are indicated by /. The number of character string is from 1 to 127 bytes. To use following
characters, specify by hexadecimal number after %.
space
& / < > # % " { } | \ ^ [ ] `
For example, specify 3 characters %20 when inserting a space in the character string. For example, to send the
character string "This is alarm.", specify as "This%20is%20alarm.". %09 and %0D are not available.
Setting Example /api/param?application.event(1).action=tcpto/10.0.0.100/20000/none/Message
To add JPEG, specify object(Number) instead of “none”.
Setting Example /api/param?application.event(1).action=tcpto/10.0.0.100/20000/object(1)/Message
Specify udpto, IP address, port number and the character string to be sent when sending via UDP. Segments are
indicated by /. The number of character string is from 1 to 127 bytes. To use following characters, specify by
hexadecimal number after %.
space
& / < > # % " { } | \ ^ [ ] `
For example, specify 3 characters %20 when inserting a space in the character string. For example, to send the
character string "This is alarm.", specify as "This%20is%20alarm.". %09 and %0D are not available.
Setting Example /api/param?application.event(1).action=udpto/10.0.0.100/20000/Message
Specify scene file number when switch scene file is specified.
Setting Example /api/param?application.event(1).action=camera.image.scene(7).status/goto
Specify preset position number when preset position is specified.
Setting Example /api/param?application.event(1).action=camera.position(2).status/goto
[VN-H57/157WP/257/257VP Only] Specify audio file number when audio file playback is specified. The audio file
number can be from 01 to 05.
Setting Example /api/param?application.event(1).action=audioplay/audiofile02/ch01
[VN-H57/157WP/257/257VP Only] Specify pinout, distinction between make/break (m1 or b1) and the time
(millisecond) when alarm output is specified. Segments are indicated by /. The time is 0 or from 100 to 5000.
When the time is 0, alarm output does not come back to previous state.
Setting Example /api/param?application.event(1).action=pinout/m1/1500
Alarm action of event number 6 is periodic FTP. Other Event number can not be set to periodic FTP. Parameters
of FTP can be set by another API, application.ftp.
Setting Example /api/param?application.event(6).action=ftpto/ftp01/object(6)