JVC 257VP Security Camera User Manual


 
Allowed users admin, operator, user
Getting Firmware Revisions
Format /api/param?system.software.revision
Example of Response system.software.revision=1.00&200 OK
Interpretation Acquire revisions of the firmware.
Allowed users admin, operator, user
Getting Software ID
Format /api/param?system.software.programid
Response Return software ID.
Response examples
system.software.programid=SPL0123&200 OK
Interpretation Acquire the software ID.
Allowed user admin
28. JVC API for Others
These are APIs of features not found on the WEB setting page.
Getting Alarm Input Status (VN-H57/157/257)
Format /api/param?peripheral.input_pin.pin(Number).status
Example of Response peripheral.input_pin.pin(1).status=make&200 OK
Interpretation Acquire the current alarm input status. Specify 1 or 2 to Number. Either make or break will be
returned.
Allowed users admin, operator, user
Getting Mode of FTP Server
Format /api/param?application.ftp.mode
Example of Response application.ftp.mode=active&200 OK
Interpretation Acquire the mode of FTP server that is used by alarm action. Either active or passive is returned.
active mode: Standard mode of FTP server. Also called PORT mode. TCP connection for data is established
from 20 port of FTP server to 10020 port of the camera.
passive mode: TCP connection for data is established from the camera to FTP server. Port number depends on
FTP server.
Allowed users admin, operator, user