JVC 257VP Security Camera User Manual


 
system.session.sending_count=2&200 OK
system.session.sending_max=5&200 OK
system.session.sending(01).bitrate=326k&200 OK
system.session.sending(01).to.ip=10.0.0.100&200 OK
system.session.sending(01).to.port=1536&200 OK
system.session.sending(01).to.protocol=tcp_passive&200 OK
system.session.sending(01).to.session=http&200 OK
system.session.sending(01).from.encode=jpeg&200 OK
system.session.sending(01).from.framerate=1&200 OK
system.session.sending(01).from.framesize=vga&200 OK
In case of H.264, system.session.sending(01).from.encode=h264baseline or h264high is returned. In case of
multicast, system.session.sending(01).to.ip becomes multicast IP address.
Interpretation Acquire the sending status of the camera. Starting and stopping stream can be occurred in
random order, so it can happen that sending(01) is vacant though sending(02) has information.
Allowed users admin, operator, user
Getting Log
Format /api/param?system.log
Response Return the following information. These information will be initialized upon turning off the power of the
camera.
Number of seconds after startup, Alarm input, Motion detect, Error
Response examples
system.log=&200 OK
system alive time: 2142sec <----- No. of seconds after startup
Dec 19 14:35:32 vn-h37 user.info evman: Motion Detect
<----- Motion detect
Dec 19 14:36:03 vn-h37 user.info evman: Alarm Detect (m1)
<----- Alarm input 1ch (make)
Dec 19 14:36:04 vn-h37 user.info evman: Alarm Detect (b2)
<----- Alarm input 2ch (break)
Dec 19 14:35:18 vn-h37 user.info evman: Motion Detect
<----- Motion detect
Interpretation Acquire the the camera log. Maximum size is 10KB.
Allowed user admin
Getting Model Name
Format /api/param?system.model
Example of Response system.model=VN-H37&200 OK
Interpretation Acquire the model name.