22
Setup
Connecting the power cable
Ⅵ TK-C1530 (AC24 V or DC12 V)
Connect the AC 24 V or the DC 12 V power cord to the power input terminal.
To prevent connection errors or a cable disconnection, we recommend the use
of lug plates.
The following table shows the connection distances when 2-core VVF
(vinyl-insulated vinyl sheath cables) are used.
Connecting the back panel
CLASS 2 ONLY(U TYPE)
ISOLATED POWER ONLY(E TYPE)
SEE INSTRUCTION
MANUAL
POWER
VIDEO OUT
SELECTOR
SET
MENU
INT LL
ONRX TERM-OFF
+
1
2
DC12V d
AC24V H
GNDAUX
To the terminal of infrared illumination device etc.(A Pg.24)
Connect to the TO CAMERA terminal of RM-P2580E
Monitor
Connect to AC
24 V or DC 12 V
power supply
(TK-C1530U/E)
Connect to AC 220 V-
240 V power supply
(TK-C1531EG)
When you install in a place where noise tend to appear, please use a cable
with a shield. A shield cable should be connected to a GND terminal.
Maximum connection distance 60 m 150 m 240 m 380 m
Conductor diameter 1.0R and
more
1.6R and
more
2.0R and
more
2.6R and
more
TK-C1530_EN.book Page 22 Friday, August 24, 2007 9:29 AM