JVC VN-C215V4U Security Camera User Manual


 
47
A Action For specifying the type of action.
Disable : Zero activation.
Mail : Send via e-mail. Specify the recipient’s mail address. The
title of the mail will appear as [Alarm from VN-C215] and
the sender as [Camera ID]. Enter the message to send in
[Mail Text]. Input of up to 127 alphanumeric characters is
allowed. To attach the latest image to the mail, set image
attachment to AOnB.
FTP : Send pre-/post-recorded JPEG files via FTP. See the
Alarm Environment Page for details on pre-/post-recording
and FTP server settings. (A Pg. 48)
The maximum transmission rate of FTP is 1 Mbps. If a new
FTP trigger occurs during post-recording, the recorded
portion is treated as pre-recording and a new post-
recording starts. During FTP transmission after finishing
the post-recording, a new post-recording starts if a new
FTP trigger occurs.
TCP : Send the character string entered in the [TCP/UDP Data]
field to the destination specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via TCP.
UDP : Send the character string entered in the [TCP/UDP Data]
field to the destination specified in [TCP/UDP IP Address]
and [TCP/UDP Port Number] via UDP.
TCP/UDP Data : Input of up to 127 alphanumeric characters.
Output1 Make : Change Alarm Output 1 to Make.
Output2 Make : Change Alarm Output 2 to Make.
Output1 Break : Change Alarm Output 1 to Break.
Output2 Break : Change Alarm Output 2 to Break.
Memo
Set the alarm output time in the [Alarm Output Duration] field.(A Pg. 50)
B 1st Trigger Specifies the first trigger to be activated.
Alarm input (AMakeB) , alarm input (ABreakB) or AMotion DetectionB can be
selected.
Memo
When the second trigger is turned AOffB, only the first trigger will be
activated.
When AMotion DetectionB is selected as the first trigger, AMax.IntervalB
and A2nd TriggerB cannot be selected.
C Max.Interval Valid only when the first and second triggers have been specified.
It dictates (determines) the maximum interval between the first and second
triggers. Activation will take place only if the interval between first and
second triggers is less than the maximum interval.
D 2nd Trigger Specifies the second trigger to be activated.
Either alarm input (AMakeB) or alarm input (ABreakB) can be selected. Unlike
the first trigger, AMotion DetectionB is not available as a choice.
VN-C215_EN.book Page 47 Monday, November 27, 2006 9:46 AM