Moxa Technologies 351 Security Camera User Manual


 
- 19 -
Hardware Reset
A recessed RESET button is provided for restoring the system to the factory
default settings. When the system fails to install properly, or operates
abnormally, push the RESET button located on the top panel of the VPort 351
to restore the factory defaults.
To restore the VPort 351 to the factory default settings, use a pointed object,
such as a straightened paper clip or toothpick, to press the reset button
continuously. When the STAT LED blinks in red, release the reset button. At
this point, the POST process will run, and the VPort will reboot. The STAT
LED will light in green when the VPort has finished rebooting.
Specifications
Video
Video Compression MPEG4, MJPEG
Video Input 1, BNC Connector
Video Output 1, Loop-through BNC Connector
NTSC/PAL Auto-sensing or Manual
Video Resolution and FPS (Frames per second):
NTSC PAL
Size Max. FPS Size Max. FPS
QVGA 320 × 240 30 320 × 288 25
CIF 352 × 240 30 352 × 288 25
VGA 640 × 480 30 640 × 576 25
4CIF 704 × 480 30 704 × 576 25
Full D1 720 × 480 30 720 × 576 25
Video Viewing
y Adjustable image size and quality
y Timestamp and text overlay
Audio
Audio Input 1 Line-in or MIC-in, 3.5mm phone jack
Audio Output 1 Line-out, 3.5 mm phone jack
Network
Protocols TCP, UDP, HTTP, SMTP, FTP, Telnet, NTP,
DNS, DHCP, UPnP, RTP, RTSP, ICMP,
IGMPv3,
QoS (ToS), SNMP (V1/V2c/V3),
DDNS
Ethernet 1 10/100BaseT(X) auto negotiating RJ45 port, or
1 100BaseFX fiber port (SC connector)
Serial Port
PTZ port 1, RS-232 or RS-422/485 Terminal Block
connector, Max. speed of 115.2 Kbps
Console port 1 RS-232 RJ45 port
GPIO
Digital Input 2, max. 8 mA
“High”: +13V to +30V
“Low”: -30V to +3V
Relay Output 2 (max. 24 VDC @ 1A)