– 122 –
MAIN Menu Screen 2 of 4 (SUB menus)
Remarks
This sets the ZEBRA1 detection level
(IRE value).
This sets the ZEBRA2 detection level
(IRE value).
This selects ON or OFF for ZEBRA2
and for setting SPOT.
FThe ZEBRA2 DETECT level should be set
higher than the ZEBRA1 detect level when
the SPOT setting is to be used. If it is set
lower, ZEBRA will not be displayed.
This sets what is to be displayed when
recording with the 50 Mbps format.
This selects the setting at which LOW
LIGHT is to be displayed when the
quantity of light entering the camera is
too low.
VF
display
USER
ENG
USER
ENG
USER
ENG
USER
ENG
USER
ENG
Variable
range
50%
.
.
.
70%
.
.
.
110%
50%
.
.
.
85%
.
.
.
110%
ON
OFF
SPOT
ON
OFF
OFF
20%
25%
30%
.
.
.
40%
45%
Item
ZEBRA1
DETECT
ZEBRA2
DETECT
ZEBRA2
50M
INDICATION
LOW LIGHT LVL
The underlining in the variable range column indicates the setting in the preset mode.
USER menu: The USER menu appears when the MENU switch is set to SET.
ENG menu: The ENG menu appears when the MENU switch is set to SET while the SHIFT/ITEM button and UP button are
held down together.
VF DI SPLAY
{
%
%
VF
DISP
DISP
CONDITION
:
:
:
:
:
:
:
:
:
:
NORMAL
MODE 3
SAFETY ZONE 3
CENTER MARK ON
OUT
VF DTL
Y
2
ZEBRA1
ZEBRA2
ZEBRA2
DETECT 070
DETECT 085
SPOT
50M INDICATION OFF
¢
|
:
ITV 45
%
LL LLO
W
GH