24
Configure the settings relating to the alarm output terminal
Select the alarm output operation. Follow the procedure below.
Step 1
Move the cursor to "ALARM IN/OUT" and press the setting button.
→ The "ALARM IN/OUT" screen appears.
Step 2
Move the cursor to "ALARM OUT" and select the alarm output terminal operation from the following.
OFF (default): Does not perform terminal output.
ALARM: The alarm output will be performed upon a i-VMD detection. The alarm output will also be performed when receiving
an alarm input while operation with setting "ALARM" for "ALARM IN".
BW: Activates the output terminal while an image is displayed in the black and white mode.
12. Privacy zone setting [PRIVACY ZONE]
When undesired portions in the camera shooting area (on the screen) exist, those portions (privacy zone) are hidden. Up to 8
portions can be specified for the privacy zone.
ON (1): Grays the zone.
ON (2): Mosaics the zone.
OFF (default): Displays the zone normally.
Follow the procedure below.
Note:
• Theprivacyzonefunctionisdisabledatinitializingtheunit,i.e.rightafterturningonthepower.
Step 1
Move the cursor to "PRIVACY ZONE", select "ON (1)" or "ON (2)", and press the setting button.
→ The zone setting screen appears.
**SYSTEM SETUP**
SYNC INT
ALARM IN/OUT
PRIVACY ZONE OFF
STABILIZER OFF
EL-ZOOM OFF
RET TOP END
"ALARM IN/OUT" screen"SYSTEM SETUP" screen
**ALARM IN/OUT**
ALARM IN OFF
ALARM OUT OFF
RET TOP END
**SYSTEM SETUP**
SYNC INT
ALARM IN/OUT
PRIVACY ZONE ON(1)
STABILIZER OFF
EL-ZOOM OFF
RET TOP END
"SYSTEM SETUP" screen Zone setting screen
**ZONE NUMBER 1 /8**
POSITION PUSH SW
UPPER LEFT
DEL
RET TOP END