-30-
To Quit Editing
• To return to the AREA TITLE menu, move the cursor
to RET, and press the CAM (SET) key.
• To cancel one area title, move the cursor to RESET
in the AREA TITLE menu, and press the CAM (SET)
key.
• To return to the SPECIAL 1 menu, move the cursor
to RET, and press the CAM (SET) key.
• To erase all the area titles, move the cursor to
RESET in the AREA TITLE (USER) selection menu,
and press the CAM (SET) key.
Notes:
• An area title appears under the camera ID if both
are set in the same position. If the setting is dif-
ferent, they appear in the area title position.
• In case of sharing a common subject in a scene
of other camera number, the nearest area title
appears while the camera direction deviates
within 45 ° from the set position. If two or more
area numbers are set in the same position, the
title of the highest number appears.
● Patrol-learn and Patrol Play (PATROL)
A routine of manual operations can be stored for 1
minute at the maximum and reproduced repetitively.
PATROL
1. Set the following parameters for the patrol-learn
starting position. These parameters are stored when
the patrol-learn mode starts.
• PAN/TILT/ZOOM/FOCUS
• IRIS
• SHUTTER
• AGC
• SENS UP
• WHITE BALANCE
•IMAGE HOLD
• AREA TITLE
• DIGITAL FLIP
• PRIVACY ZONE
• CAMERA ID
•PROPO.PT
• PAN LIMIT
• ZOOM LIMIT
• TILT ANGLE
• BURST
• CLEANING
After starting the patrol-learn, the following manual
operations are stored.
• PAN/TILT/ZOOM/FOCUS operation
• IRIS operation
• Preset positioning
2. Open the SET UP menu and move the cursor to
SPECIAL 1. For PATROL, select LEARN, PLAY or
STOP with the joystick.
The factory default setting is STOP.
LEARN: A series of manual operations is stored.
PLAY: Stored operations are reproduced.
STOP: LEARN or PLAY is not activated.
PATROL LEARN with a Controller Having PATROL
Key
1. Press the PATROL key and the CAM (SET) key
simultaneously to start patrol-learn. The setup menu
displays "LEARNING(60S)", and the starting points
are stored.
2. Operate patrol-learn manually. The operation data is
stored. The countdown to complete learning is dis-
played.
3. To stop patrol-learn, press the PATROL STOP key.
Patrol-learn with a Controller not Having the
PATROL Key
1. Close the SET UP or SPECIAL 1 menu to start
PATROL LEARN. Starting point parameters are
stored and "LEARNING(60S)" is displayed on the
monitor.
2. Operate patrol-learn manually.
NORTH
** SPECIAL 1 **
PRIVACY ZONE OFF
PROPO.P/T ON
AREA TITLE ON(USER)
PATROL PLAY
ALARM IN/OUT
CLEANING OFF
EL-ZOOM ON
PRESET ALM OFF
IMAGE HOLD OFF
TILT ANGLE 0°
RET
LEARNING(60S)