Pelco 90 Security Camera User Manual


 
12 C2462M-D (3/08)
IN-CEILING INSTALLATION: FIXED CEILING/WALL
Refer to Figure 6 and complete the following steps.
1. Cut a 4-inch diameter hole in the ceiling/wall.
2. Remove the surface mount ring from the back box. Refer to Figure 5 and complete the following
steps:
a. Place your fingers on the circular marks located on the sides of the surface mount ring.
b. Pinch the sides.
c. Lift and remove the surface mount ring from the back box.
3. Connect the video cable/wires.
BNC: Connect the BNC connector from the Camclosure to a mating BNC connector.
Twisted pair: Connect the blue wire to Video +; connect the gray wire to Video -.
4. Connect the power wires.
AC Operation Only: If you are wiring more than one ICS090 Camclosure to the same transformer,
connect one side of the transformer to the red wire on all units, and then connect the other side of the
transformer to the black wire on all units. Failure to connect all of the units in the same way will cause
the cameras to be out of phase with each other, which might produce a vertical roll when switching
between cameras.
5. Use the 3-16 toggle bolts (not supplied) to attach the back box to the mounting surface.
Figure 6. In-Ceiling Installation to a Fixed Ceiling/Wall
Table C. Power Input: Fixed Ceiling/Wall Installation
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC ~ ~