10 C4601M-C (7/11)
Equipment Placement and Rack Mounting
The Endura workstation can be placed on a flat surface, such as a desktop, or mounted in an equipment rack.
DESKTOP MOUNTING
To mount the Endura workstation on a desktop:
1. Verify that the rubber feet are securely installed on the four corners of the bottom of the unit to prevent surface damage.
2. Remove the two chassis brackets (if attached) from the sides of the unit, using a Phillips screwdriver to remove the eight 10-32 x 0.25-inch
Phillips pan head screws (supplied, four per bracket). Save the brackets and screws for possible future use.
3. Position the unit to allow for cable and power cord clearance at the rear of the unit. Be sure that the air flow around the unit is not
obstructed.
Figure 5. Chassis Brackets and Rubber Feet
WARNING: Do not place the Endura workstation unit on its side; in this position, the unit is likely to fall over and may cause equipment
damage or personal injury.
(4) SCREWS
PER BRACKET,
10.32 X 0.25-INCH
PHILLIPS PAN HEAD
CHASSIS
BRACKET
RUBBER FEET
(4) SCREWS,
8-32 X 0.25-INCH
PHILLIPS PAN HEAD