Raise the mirror up and open the shutter to clean with a blower. Please
contact PENTAX Service Center for professional cleaning because the
CMOS sensor is a precision part. Cleaning services involve a fee.
You can use the Imagesensor Cleaning Kit O-ICK1 (optional) when
cleaning the CMOS.
1
Turn the camera off and remove the lens.
2
Turn the camera on.
3
Select [Sensor Cleaning] in the [R Set-up] menu.
Removing Dust with a Blower
Do not use a spray type blower.
Do not clean the sensor when the exposure mode is set to p (Bulb) mode.
Always cap the lens mount area to prevent dirt and dust from accumulating
on the CMOS sensor when no lens is on the camera.
When the battery level is low, [Not enough battery remaining to clean sensor]
is displayed on the monitor.
If you are not using the AC adapter D-AC50, please use a battery with ample
capacity remaining. If the battery capacity becomes low during cleaning, a
message will be displayed on the monitor and a warning beep will sound.
Please stop cleaning immediately.
Do not put the tip of the blower inside the lens mount area. If the power is
turned off, this could cause damage to the shutter, CMOS sensor or the
mirror.
It is recommended to use the AC adapter D-AC50 (optional) when cleaning
the sensor.
The self-timer lamp blinks and [Cln] appears on the LCD panel while cleaning
the sensor.
This camera features a CMOS sensor shifting shake reduction system, and
it may generate a vibration sound while cleaning the CMOS sensor. It is not
a malfunction.