Philips TDA8783 Security Camera User Manual


 
2002 Oct 23 7
Philips Semiconductors Product specification
40 Msps, 10-bit analog-to-digital
interface for CCD cameras
TDA8783
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 60134).
Note
1. The supply voltages V
CCA
, V
CCD
and V
CCO
may have any value between 0.3 and +7.0 V provided that the supply
voltage difference V
CC
remains as indicated.
HANDLING
Inputs and outputs are protected against electrostatic discharges in normal handling. However, to be totally safe, it is
desirable to take normal precautions appropriate to handling integrated circuits.
THERMAL CHARACTERISTICS
SYMBOL PARAMETER CONDITIONS MIN. MAX. UNIT
V
CCA
analog supply voltage note 1 0.3 +7.0 V
V
CCD
digital supply voltage note 1 0.3 +7.0 V
V
CCO
output stages supply voltage note 1 0.3 +7.0 V
V
CC
supply voltage difference
between V
CCA
and V
CCD
1.0 +1.0 V
between V
CCA
and V
CCO
1.0 +4.0 V
between V
CCD
and V
CCO
1.0 +4.0 V
V
i
input voltage referenced to AGND 0.3 +7.0 V
V
CLK(p-p)
AC input voltage for switching
(peak-to-peak value)
referenced to DGND V
CCD
V
I
o
output current 10 mA
T
stg
storage temperature 55 +150 °C
T
amb
ambient temperature 20 +75 °C
T
j
junction temperature 150 °C
SYMBOL PARAMETER CONDITIONS VALUE UNIT
R
th(j-a)
thermal resistance from junction to ambient in free air 76 K/W