Philips Video Camera Digital Camera User Manual


 
12
13
2.5 Setting Protocol of Dome Camera
If a dome camera is to be installed with a Fastrax keyboard controller, select F2 protocol.
Consult service personnel if a dome camera is installed with device other than a keyboard controller.
Unless Baud rate match, universal protocol will not work.
Figure 13 – Protocol Selection Switches
D11 D12
Camera
S6-3 S6-4
Off Off Default cameras (Default)
Off On Reserved
On Off Reserved
On On Reserved
S/W
On Off Function
D1 S4-1 Enable Disable Alarm
D2 S4-2 PAL NTSC NTSC/PAL
D3 S4-3 Endless
D4 S4-4 RS-422 RS-485 RS-422/RS-485
D5 D6 D7
Protocol
S5-1 S5-2 S5-3
Off Off Off
Fastrax, Pelco D&P, Dynacolor, Ernitec &
Philips G3 Protocol (Default)
Off Off On Reserved
Off On Off Sensormatic RS-422
Off On On Reserved
On Off Off Vicon Protocol
On Off On Reserved
On On Off Dynacolor
On On On Reserved
D8 D9 D10
Baud Rate
S5-4 S6-1 S6-2
Off Off Off 2400 bps
Off Off On 4800 bps
Off On Off 9600 bps (Default)
Off On On 19200 bps
On Off Off 38400 bps
On Off On 57600 bps
On On Off 115200 bps
On On On 230400 bps