Alarm Output
Setting 1
þ1 þ2 þ
MD
þ
AUX
Setting 2
þ1 þ2 þ
MD
þ
AUX
Timer 1 OFF
Timer 2 OFF
OUT Off 1
OUT Off 2
ª
29.2. Alarm Output
Ķ
Main Menu/Alarm Setting/Alarm Output
Timer
1,2 :
Enables selecting an Alarm Output method.
- On : Retains an alarm output for a set duration from a
minimum of 1 second to a maximum of 60 minutes
upon the alarm occurrence.
- Momentary : Retains an alarm output only until the alarm is
canceled.
Setting 1,2 :
Enables selecting an Alarm Output method.
- 1, 2, Motion, and Support Device indicate alarm input
ports, Motion Detection, and support device input. A total of
4 alarms, Motion Detection, and support devices can be set
up to output alarms. 1 alarm output port can be used for
more than 2 alarm inputs and Motion Detection.
The Alarm Output is equipped with a relay circuit. The
operation of the alarm output port is as shown in the
diagram below. (Normally Opened)
• Connecting the power connector and GND incorrectly to the NC/NO and COM ports may
cause a short circuit and fire, damaging the camera.
The maximum power capacity of the built-in relay is 30VDC/2A, 125VAC/0.5A, and
250VAC/0.25A. Operating the camera beyond the capacity may decrease the camera’s
lifespan and damage it.
Notes
B
NO NO
NC NC
COM COM
Alarm Out OFF
Alarm Out ON
ª
Alarm Setting
Alarm Enable OFF
Alarm Input
Alarm Output
MD Dwell Time OFF