COLOR IR CAMERA User’s Manual
21
Using a RS-485 communication, it will be able to control the OSD menu at the
SAMSUNG TECHWIN System Controller or DVR.
(1) The case which it controls from the PC
Using a RS-485 converter, It connects to RS-485 CONTROL TERMINAL outside
camera and serial cable
EX) SERIAL PORT OF THE PC(COM1) — SERIAL CABLE -- RS-485 CONVERTER
-- RS-485 CONTROL TERMINAL
(2)The case which it controls from the DVR or System Controller
It connects the RS-485 CONTROL TERMINAL in the connection terminal of 485
control boards which are connected with the DVR or System Controller.
Connecting to RS-485 CONTROL TERMINAL
• When you construct external control systems for a camera control, please use to
the PELCO-D PROTOCOL.
Notes
CONTROL TERMINAL
SPEC
WHITE (TRX+) RS-485+
BLACK (TRX-) RS-485-
485 CONTROL BOARD CONNECTION TERMINAL RS-485 CONTROL TERMINAL
(+)CONNECTION TERMINAL WHITE (TRX+)
(-)CONNECTION TERMINAL BLACK (TRX-)
Menu
Connection
COLOR IR CAMERA User’s Manual
21
COLOR IR CAMERA User’s Manual
20
RS-485 communication control
Operating Your Camera
SETUP menu
LENS • DC
SHUTTER
• ---- • FLK
(condition and speed control)
WHITE BALANCE control
• ATW • AWC • MANUAL
BACKLIGHT
• OFF • LOW • MIDDLE
(Backlight compensation) • HIGH
AGC (Auto Gain control) • OFF • NORMAL • HIGH
SSNR
• OFF • LOW • MIDDLE
(Samsung super noise reduction)
• HIGH
SENS-UP (Low illuminance)
• OFF • AUTO
•
CAMERA ID • DAYNIGHT
SPECIAL
• MOTION DET • PRIVACY
• COMM ADJ • IMAGE ADJ
• RESET • RETURN
EXIT