5554
Functional Description
Language : The OSD can be displayed either in English (default setting) , Chinese,
French, German, Italy and Spanish
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
OSD Setting
Camera ID ON
Camera Name
Preset Number ON
Preset Name
Sequence Status OFF
Area Name OFF
PTZ Position ON
Language English
Output Clear : If you want to cancel the operating Alarm outputs at once, select
the corresponding menu to cancel the operating Alarm.
Input 1, Input 2 : Alarm Input Mode/Priority/Method is set up.
Enable : It can be determined whether to enable the alarm setting.
ON/OFF : Alarm is enabled in ON mode.
NC/NO/OFF : NC/NO/OFF can be selected depending on the alarm sensor.
L/H (Priority) : Priority for the 2 alarm inputs is set up. Response comes first from
the alarm input of higher priority.
Preset/Swing/Group/Tour/Trace/A.PAN :
Whether to enable the operation of Preset/Swing/Group/Tour/Trace/A.PAN by alarm
input can be set up. When the alarm is input, it stays in the Preset/Swing/ Group/
Tour/Trace/A.PAN position.
5) Alarm Setting
Output : One of the 2 Alarm Outs and MD(Motion Detection) corresponds to
each Alarm input.
For the 2 Alarm Outputs, On/Off and the operation time can be set up in the units of
second/minute/hour. (1-59 sec, 1-59 min, 1-59 hour)
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
Alarm Setting
Output Clear
Input 1 OFF
Input 2 OFF
Output OFF
Enable OFF
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 NO L PRESET 031
Input 2 NC H PRESET 031
Output ON *1*2 MD 03SEC
Enable ON
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 OFF
Input 2 OFF
Output OFF
Enable OFF
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 NO L PRESET 031
Input 2 NC L PRESET 031
Output ON *1*2 MD 03SEC
Enable ON
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 OFF
Input 2 OFF
Output OFF
Enable OFF
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 NO L PRESET 031
Input 2 NC L PRESET 031
Output ON *1*2 MD 03SEC
Enable ON
MD Dwell Time ON 30 SEC
Alarm Setting
Output Clear
Input 1 OFF
Input 2 OFF
Output OFF
Enable OFF
MD Dwell Time ON 30 SEC