1312
Camera Initial Settings
Setting Baud Rate Based on DVR Model
If the speed dome camera is controlled not by the camera controller but by a
DVR, set the communication speed based on the DVR model as follows.
Part Names and Functions
• Default Setting : Samsung 9,600 bps
• When you set up, refer to rear panel number(Ignore, DIP SWITCH number).
• Please see our homepage for details on the protocol
Notes
Setting Communications Protocol
Use the SW2 #1~#5 of installation bracket to set the communications protocol.
Setting Transmission Mode
Set the transmission mode using the ON/OFF of the Rear Panel SW2.
Samsung Pelco Samsung Elec.
SVR-950 9600,19200 2400,4800 19,200
SVR-1640 9600,19200 2400,4800 19,200
SVR-1650 9600,19200 2400,4800 19,200
Protocol
DVR Model
Function ON OFF
SW2- #6 Transmission Mode Full Half
Selection (DVR) (SCC-3100A)
• Factory Setting: OFF
• When you set up, refer to rear panel number(Ignore, DIP SWITCH number).
Notes
Rear panel Number
Rear panel Number
Protocol
Baud Rate(BPS)
SW2-#1 SW2-#2 SW2-#3 SW2-#4 SW2-#5
Samsung 9,600 OFF OFF OFF OFF OFF
Samsung 19,200 OFF OFF OFF OFF ON
Pelco-D 2,400 OFF OFF OFF ON OFF
Pelco-D 4,800 OFF OFF OFF ON ON
Pelco-P 4,800 OFF OFF ON OFF OFF
Pelco-P 9,600 OFF OFF ON OFF ON
Samsung Elec. 9,600 OFF OFF ON ON OFF
Samsung Elec. 19,200 OFF OFF ON ON ON
Panasonic 9,600 OFF ON OFF OFF OFF
Panasonic 19,200 OFF ON OFF OFF ON
Vicon 4,800 OFF ON OFF ON OFF
Vicon 9,600 OFF ON OFF ON ON
AD 4,800 OFF ON ON OFF OFF
Bosch 9,600 OFF ON ON OFF ON
Bosch 19,200 OFF ON ON ON OFF
Honeywell 9,600 OFF ON ON ON ON
Honeywell 19,200 ON OFF OFF OFF OFF
SUNGJIN 4,800 ON OFF OFF OFF ON
Pelco-D 9,600 ON OFF OFF ON OFF
Reserved