Extend the cable-management arm and fasten the
cables:
Attention: Make sure that you route Fibre
Channel cables through the tab 1, to ensure
proper bend radius and prevent damage to these
cables.
Extend the cable-management arm by sliding the
server toward the front of the rack. The rail-lock
pins stop the server halfway along the rack. Secure
the cables by using the straps that are attached to
the cable-management arm.
Slide the server back into the rack cabinet.
8
Secure the server to the rack:
Before you transport the rack cabinet to another
location with the server installed, you must secure
the server to the rack. If necessary, disconnect the
cables from the rear of the server; then, slide the
server out of the rack 150 mm (6 in.) and insert the
M6 screws in each slide rail. Then, secure the server
to the rack cabinet with the M6 screws and
reconnect the cables.
To remove the server from the rack, reverse these instructions. Store this information with your server
documentation for future use.