Technicolor - Thomson LDK 20(S) Digital Camera User Manual


 
Adjustments Technical Manual LDK 20(S) - Studio Camera 4-23
Video Miscellaneous Board
Black indicator level
25. Use the controls at the rear of the camera to set the white indicator level for the monitoring output by navigating
through the menu system to menu number 318 and setting the value to 85.
26. Connect oscilloscope terminated with 75 Ohm to the VF output of the camera.
27. Adjust the black level of the indicators of the VF output signal to the same level as the blanking.
Measure at: Adjust with: Required result: Correct: Incorrect:
VF output ZR47
0%
10
90
100
0.2V
10µS
VB+714mV
0%
10
90
100
0.2V
10µS
VB+714mV
28. On connector B of the service extender remove the short circuits on the input to Video Processor 1 Board
by disconnecting the jumpers fromB7 to B9
B11 to B13
B17 to B19
Reconnect A7 to B7
A9 to B9
A11 to B11
A13 to B13
A17 to B17