Vivotek 63E-M Security Camera User Manual


 
VIVOTEK
User's Manual - 13
Combine the components of the top section.
1. Press the seal ring into the groove on the interface section. Use the black machine screws
(M4x8) to attach the interface section to the dome cap. Note that you should orient and align
the spring contacts with the dehumidier unit on the dome cap.
2. Secure the dome cap to the mount bracket.
3. Use the included hex wrench to secure the connection.
When done, the top section will look
like this. You can now carry the cam-
era and the top section
to the installation site.
Mount
Bracket
Interface Section
Board-to-board
Connector
Dehumidier Unit
1-3. Connect with the Mount Bracket
1
2
3
Seal Ring