VIVOTEK
User's Manual - 187
7.35 Storage management setting
Currently it’s for local storage (SD, CF card)
Group: disk_i<0~(n-1)> n is the total number of storage devices. (capability.storage.dbenabled > 0)
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
cyclic_enabled <boolean> 0 6/6 Enable cyclic storage method.
autocleanup_enabled <boolean> 0 6/6 Enable automatic clean up method.
Expired and not locked media files will
be deleted.
autocleanup_maxage <positive
integer>
7 6/6 To specify the expired days for
automatic clean up.
7.36 Object tracking setting
Group: sdobjtrack.
PARAMETER VALUE Default SECURITY
(get/set)
DESCRIPTION
objsize_type -1~2 -1 1/4 Type of object size.
-1 : customized width and height
0 : object size = 30 x 30
1 : object size = 10 x 20
2 : object size = 10 x 10
objsize_customized_widt
h
10~320 30 1/4 The minimum width of tracking
target.
objsize_customized_heig
ht
10~240 30 1/4 The minimum heght of tracking
target.
sensitivity 0~2 1 1/4 Tracking sensitivity.
0 : Low
1 : Medium
2 : High