Vivotek 63E-M Security Camera User Manual


 
VIVOTEK
User's Manual - 179
trigger boot,
di,
motion,
seq,
recnotify,
volalarm,
vi
boot 6/6 Indicate the trigger condition:
“boot” = System boot
“di”= Digital input
“motion” = Video motion detection
“seq” = Periodic condition
“recnotify” = Recording notification.
“volalarm” = Audio detection.
“vi” = Virtual input.
triggerstatus String[40] trigger 6/6 The status for event trigger
exttriggerstatus String[40] <blank> 6/6 The status for event trigger
exttriggerstatus1 String[40] <blank> 6/6 The status for event trigger
exttriggerstatus2 String[40] <blank> 6/6 The status for event trigger
exttriggerstatus3 String[40] <blank> 6/6 The status for event trigger
di 0~15 1 6/6 Indicate the source id of di trigger.
This field is required when trigger
condition is “di”.
One bit represents one digital input.
The LSB indicates DI 0.
mdwin 0~7 0 6/6 Indicate the source window id of
motion detection.
This field is required when trigger
condition is “md”.
One bit represents one window.
The LSB indicates the 1
st
window.
For example, to detect the 1
st
and 3
rd
windows, set mdwin as 5.
mdwin0 0~7 0 6/6 Similar to mdwin. The parameter
takes effect when profile 1 of motion
detection is enabled.
valevel <boolean> 0 6/6 Enable/Disable audio detect.
valevel0 <boolean> 0 6/6 Enable/Disable audio detect profile.
vi 0~7 0 6/6 Indicate the source id of vi trigger.
This field is required when trigger
condition is “vi”.
inter 1~999 1 6/6 Interval of snapshots in minutes.
This field is used when trigger
condition is “seq”.