4.5 Control Displays Error Messages
The following error message screens appear whenever the Control
Display detects a problem with the system. Once a problem occurs
and the error message appears, the system will shut down.
Before proceeding, follow the Pressure Relief
Procedure outlined in this manual. Additionally,
follow all other warnings to reduce the risk of an
injection injury, injury from moving parts or electric
shock. Always unplug the system before servicing!
Check Transducer Screen
The Check Transducer screen appears
when the transducer has become
disconnectedorisdefective.TakethesprayertoaTitanauthorized
service center for repair.
Check Potentiometer Screen
POTENTIOMETER
The Check Potentiometer screen appears
when the potentiometer has become
disconnectedorisdefective.TakethesprayertoaTitanauthorized
service center for repair.
Low Voltage Screen
TheLowVoltagescreenappearswhen
the sprayer shuts down because of low
input voltage. Check the power supply and correct the problem.
Restart the system.
High Motor Temperature Screen
The High Motor Temperature screen
appears when the temperature of the
motorhasrisentoohigh.TakethesprayertoaTitanauthorized
service center for repair.
High Mechanical Load
LOAD
The High Mechanical Load screen
appears when the sprayer shuts down
because of high current or when the sprayer goes into current fold
backmode.TakethesprayertoaTitanauthorizedservicecenterfor
repair.
PSI Imbalance
The PSI Imbalance screen appears
when there is a non-allowable pressure
discrepancy between the (A) and (B) pumps while linked. If a PSI
imbalance occurs, press the #3 key to unlink the two pumps. Once
the pumps are unlinked, press the #1 key to return to the Main
Screen.
14 Helix
GB
Control Panel
Security Code Screen*
SECURITY CODE
CHANGE-2MENU-1
The Security Code screen allows the
user to set a four digit security code to
preventunauthorizeduseofthesprayer.Ifasecuritycodehasbeen
set, the control system display will ask for the code at startup. If the
correct code is entered, the display will show the Main Screen and
the sprayer will operate. If the wrong code is entered, the display will
continue to ask for the correct code and the sprayer will be disabled.
To set or change the security code, press the #2 key.
i
If the sprayer is new, no security code is set and the
Main Screen will appear at startup. When setting a
security code for the rst time, the “Enter Old Code
Number” screen will appear, and you will need to
enter “1111”.
NUMBER
Enter the old security code number to
access the screen that allows the code
change. If the wrong code is entered, the
display will continue to ask for the correct
code and the security code cannot be
changed.
NUMBER XXXX
RE-ENTER NEW
NUMBER XXXX
NEW CODE NUMBER
ACCEPTED
Enter the new security code. Once the
new code is entered, the display will
automatically ask that the new code be
re-entered for verication. If the same
new code is re-entered, the display will
conrm that the new code has been
accepted and return to the Main Screen.
If the new code is re-entered incorrectly, the display will return to the
“EnterNewCodeNumber”screenandtheprocesswillrepeat.
If you forget or misplace your security code, you can call Titan
customer service for assistance.
i
To inactivate the Anti-Theft Digital Lockout security
function, enter “1111” at the “Enter New Code
Number” screen (this is the default code that leaves
the sprayer unlocked). As a result, the Main Screen
will appear at sprayer startup.
Prime Screen
The Prime screen appears when the
pressurecontrolknobissetatthe“MIN”
setting.
If there is no action at any menu screen for 10
seconds, the display will go back to the Main Screen.