Viewing Dome Operating Statistics
When Dome Statistics is selected from the Dome Information screen, the following information
is displayed:
DOME STATISTICS
PanStat TiltStat ZoomStat
R 000000C9 00000085 00000011
L 0000006A 00000074 00000012
M 000001B5 00000089 00000048
T 00000013 00000017 0000000E
Pwr/Run Pwr/Run
O 00007615 W 00000000
P 00000000 U 00000000
EXIT
From this screen, you can identify the operating statistics for various features of the dome. The
information represents either runtime in seconds or number of occurrences (displayed in hexadecimal
values). The following table describes the abbreviations used.
Abbreviation Description
R
Time moving right in seconds.
L
Time moving left in seconds.
M
Total move time in seconds.
T
Total target count.
O
Operating time in seconds.
P
Power failure reset count.
W
Watchdog reset count. The watchdog tracks software problems that
cause the dome to hang. This number should be zero.
U
User reset count. This represents the resets initiated by the dome
operators.
When you are finished viewing the dome statistics, select Exit to return to the Dome Information
screen.
SpeedDome Ultra VII Day/Night Operator's Manual 7
–