Axis Communications 243SA Security Camera User Manual


 
55
AXIS 243SA - System options
SNMP
The Simple Network Management Protocol (SNMP) allows the remote management of
network devices. Select the version of SNMP to use, depending on the level of security
required. Select the version of SNMP to use, by checking the appropriate box. The three
levels of security are:
SNMP V1 - includes no security
SNMP V2c - uses very simple security, for example,
community name as pass-
word
SNMP V3 - provides encryption and secure
passwords. Use with HTTPS.
If using V1 and V2c, enter the community name for read-only access to all supported
SNMP
objects (except the root password and other objects that require write access).
Default value = public. You can also specify the community name for read/write access to
all supported SNMP objects (except read-only objects). Default value = pass.
If using HTTPS enter the password if it has not already been set. T
o set the password again,
the Axis video server must be reset to the factory default settings.
UPnP™
The video server includes support for UPnP™. UPnP™ is enabled by default, and the video
server then is automatically detected by operating systems and clients that support this
protocol.
Note:
UPnP™ must be installed on your workstation if running Windows XP. To do this, open the Control Panel
from the Start Menu and select Add/Remove Programs. Select Add/Remove Windows Components and
open the Networking Services section. Click Details and then select UPnP™ as the service to add.
RTP (Multicast)/MPEG-4
These settings are the IP address, port number, and Time-To-Live value to use for the
media stream(s) in multicast MPEG-4 format. Only certain IP addresses and port numbers
should be used for multicast streams. For more information, please see the online help.
Bonjour
Your Axis network camera includes support for Bonjour. When enabled, the camera is
automatically detected by operating systems and clients that support this protocol.
Ports & devices
I/O Ports - the pinout, interface support and the control and monitoring functions
provided by this connector are described in Unit connectors,
on page 60.
RS232
- The COM port RS-232 on the AXIS 243SA supports several operational modes
listed on this page. For more information, please see COM ports RS-232 and RS-485, on