Bosch Appliances NBN-498 Digital Camera User Manual


 
36 en | Installation Dinion2X IP Camera
AR18-10-B006 | v1.1 | 2010.06 Installation and Operation Manual Bosch Security Systems
3. Press and hold the center key for more than 2 seconds
until the Install menu appears.
4. Select Len Wizard and move cursor to the Set Back Focus
Now item.
5. Turn the back focus adjustment as required.
6. Lock the back focus locking button.
7. Press and hold the center key for more than 2 seconds
until all the menus disappear.
8. Close the side door panel.
5.11 Lens adjustment
5.11.1 DC-iris lens
1. Unlock the back focus locking button.
2. Access the Lens Wizard menu.
3. Set Back Focus Now is highlighted in the menu.
4. Turn the back focus adjustment as required.
5. Lock the back focus locking button.
6. Exit the menu.
5.11.2 Manual-iris lens
1. Unlock the back focus locking button.
2. Adjust the lens to the maximum lens opening.
3. Turn the back focus adjustment as required.
4. Lock the back focus locking button.
Bosch