Bosch Appliances NBN-498 Digital Camera User Manual


 
Dinion2X IP Camera Camera set-up | en 39
Bosch Security Systems Installation and Operation Manual AR18-10-B006 | v1.1 | 2010.06
6.2 Install menu
When the Install menu is opened, the MAC address of the unit
is shown. This is factory set and cannot be changed. (To ensure
that the correct MAC address is displayed, wait 20 seconds
after power-up before opening the Install menu.)
The items in the Install menu include the Mode selection, the
Lens Wizard submenu, the Network submenu, and the Defaults
submenu.
Note:
Camera parameter set-up is done via IP. See
Section 9.6 Camera for the specific camera menus.
6.2.1 Pre-defined modes
There are six pre-defined modes with settings to make
configuration easier. Select one of the six pre-defined modes in
the Install/Mode submenu. The modes are defined as follows;
1. 24-hour
Default installation mode to provide stable pictures over a
24-hour period. These settings are optimized for out-of-
the-box installation.
2. Traffic
Capture high-speed objects using default shutter in
variable lighting conditions.
3. Low light
Provide extra enhancement, such as AGC and SensUp to
make usable pictures in low-light conditions.
4. Smart BLC
Settings optimized to capture details in high contrast and
extremely bright-dark conditions.
5. Low noise
Enhancements are set to reduce picture noise. Useful for
conditional refresh DVR and IP storage systems because
reducing noise reduces the amount of storage required.