5.15 Alarm Inputs
You can configure the alarm inputs of the VIP XD.
Alarm input
Select Active high if the alarm is to be triggered when the contact closes. Select Active low if
the alarm is to be triggered when the contact opens.
Name
For easier identification, you can enter a name for each alarm input.
5.16 Relay
You can configure the switching behavior of the relay output. You can specify an open switch
relay (normally closed contact) or a closed switch relay (normally open contact).
You can also specify whether the output should operate as a bistable or monostable relay. In
bistable mode, the triggered state of the relay is maintained. In monostable mode, you can set
the time after which the relay will return to the idle state.
You can select different events that automatically activate the output. It is possible, for
example, to turn on a floodlight by triggering a motion alarm and then turning the light off
again when the alarm has stopped.
Idle state
Select Open if you want the relay to operate as an NO contact, or select Closed if the relay is
to operate as an NC contact.